WHAT DEFINES THEM?
REI120 telescopic fire rated gates are available as horizontal sliding doors.
The field of use includes large openings and/or special usage conditions in customer-specified dimensions. Gates
are supplied with leaves made of flush insulated sheet metal panes, sliding guides, protective carters, counterweights,
thermal fuses or electromagnets and finished in a base coat or RAL colors, plus other accessories as required for correct product functioning.
Standards
The gates are certified in accordance with UNI 9723 standards in compliance with the current ministerial provisions
in force.
Opening direction
Opening direction needs to be indicated while placing the order.
Bilateral Telescopic Gates available in class:


Particular care must be taken to check for protrusions or blockages that might hinder the operation or free movement of the gates. Given the considerable weight of gates, the bearing capacity of the walls and crossbeams involved should be checked for the mounting of top guide tracks and overlapping labyrinths.
Compartmentalization for interiors is for areas that are not subject to strong air currents. Installation to be executed by specialized technicians only. For special applications consult with our technical office.
The holding system for the gate is chosen by the customer to conform with their own worksite needs and the anti-fire design (thermal fuse or electromagnet).
REI 120 MONOLATERAL VERSION WITH TWO LEAVES
In conformity with UNI 9723 for two leaves, the telescopic mono-lateral gates series has the following characteristics:
Installation
On weight-bearing masonry walls or ceilings.
Gate leaves
Made of continuous panels of hollow-core sheet metal insulated with appropriate materials. Assembly involves screwing the structure to pre-prepared horizontal profiles. Leaf thickness 80 mm.
Top guide track
For horizontal sliding, made of press-folded steel with predrilled holes for attachment using plugs (not included). Overhead sliding on low friction carriages. The extension of the floor-mounted guide track beyond the opening ensures the perpendicularity of the leaf. The top guide track is covered by a protection carter made of press-folded sheet metal.
Overlapping labyrinths
Made of press-folded steel.
Counterweight
For adjustable closure and protected by press-folded sheet metal carters, with counterstrike inset and shimming inset.
Door handles
Recessed on both sides of the first leaf.
Sealing
Thermo-expanding on all overlapping labyrinths and underneath the leaf.
Identification plate
Marking with reference information that is applied directly to the handle.
Finishing
With a base coat thermoset in a 160 degree C furnace, light turquoise pastel color (similar to NCS4020-B50G).
Packaging
Modules in disposable metal container.
Wall opening dimensions
On request as shown in the table to the side (smaller and larger sizes on request).
Operation mode
Of the gate series with thermal fuse: the gate can stand still at any position. The counterweight remains hooked to the thermal fuse and only closes the gate when the fuse fails.
Weight
For the Telescopic Gates , approx. 50 kg/m2 of wall opening
NOTE: Additional accessories are usually dependent on the size dimensions of the gates

NB: Guide track gradient of 2 mm/ml

*Variable dimensions for larger-sized gates

REI 120 BILATERAL VERSION WITH FOUR LEAVES
Conforms with UNI 9723 for four leaves, the telescopic bilateral gates series has the following features:
Installation
On weight-bearing masonry walls or ceilings.
Gate leaves
Four leaves made of continuous modules of hollow-core sheet metal panels insulated with the appropriate materials.
Assembly involves screwing the structure to pre-prepared horizontal hollow metal profi le. Leaf thickness 80 mm.
Top guide track
Double-guide for horizontal sliding made of press-folded steel with pre-drilled holes for attachment using plugs
(not included). Overhead sliding on low friction carriages. The extension of the fl oor-mounted guide track beyond the opening ensures the perpendicularity of the leaves. The top guide track is covered by a protection carter made of press-folded sheet metal.
Overlapping labyrinths
Made of press-folded steel.
Counterweight
For adjustable closure and protected by press-folded sheet metal carters, with for the counterstrike and shimming insets.
Door handles
Recessed on both sides of the first two leaves.
Sealing
Thermo-expanding on all overlapping labyrinths and underneath the leaves.
Identification plate
Marking with reference information that is applied directly to one of the handles.
Finishing
With a base coat thermoset in a 160 degree C furnace, light turquoise pastel color (similar to NCS4020-B50G).
Packaging
Modules on disposable metal container.
Wall opening dimensions
On request as shown in the table to the side (smaller and larger measures available on request).
Operation mode
Of the gate series with thermal fuse: the gate can stand still at any position. The counterweight remains hooked
to the thermal fuse and only closes the gate when the fuse fails.
Weight
For the Telescopic Gates , approx. 50 kg/m2 of wall opening
NOTE: Additional accessories are usually dependent on the size dimensions of the gates

NB: Guide track gradient of 2 mm/ml

*Variable dimensions for larger-sized gates

OPERATION MODE OF TELESCOPIC FIRE GATES
The selection of the holding system should reflect the customer’s worksite needs and the anti-fire project.
Operation mode of gates equipped with thermal fuse:
The counterweight (1) does not load the gate and the operator (2) manually opens and closes the gates, which remains in the position it is left in. When the thermal fuse (3) is subjected to temperatures greater than 70° C, it
breaks and causes the cable (4) to be released, so that the counterweight drags the gates to the closed position. The
feed speed brake (5) prevents the gates from accelerating during closure. The feed-in impact absorber (6) softens the final feed-in impact of the closure.
Operation mode of gates equipped with electromagnet:
The counterweight (1) continuously loads the gate. The gate usually remains open, held in place by the electromagnet
(2). The counterweight closes the gate whenever the electromagnet lacks impulse current from the control unit or when the release button (3) is pressed. The feed speed brake (4) prevents the gate from accelerating during closure. The feed-in impact absorber (5) softens the final feed-in impact of the closure. The electromagnet must be connected with a power control unit and the related external smoke and heat detectors.


INSTALLATION
PAINTING
With ecologically formulated anti-corrosive epoxide primer. Minimum resistance to salt fog exposure: 300 hours (A.S.T.M. B – 117 – 61). Basic anti-corrosion coating: Light turquoise pastel. Optional: finishing with satin topcoats
from the selection of furnace polymerized RAL colors.
Group 01
Gates color: light turquoise pastel (similar to NCS4020B50G)
Group 02 (Basic anti-corrosion coating + satin topcoat finishing):
Cleaning
Water and neutral soap are recommended for the regular cleaning of our products. Do not use common cleaning products (see detergents) and/or other solvents. We shall not be held responsible for any problems that arise if these
guidelines are not respected.
Re-painting
For re-painting, use the following procedure:
- sand and carefully wipe away any dust from the surfaces
- apply a base layer of opaque 2-component epoxide we recommend EPOX product Nr. 5203 beige 0059 made by ALCEA in Milan
- repaint the surfaces with your choice of lacquers or paints.


*Pre-approval of the sample is required.

In general, all RAL tints are useable except for: RAL 1018, RAL 5005 and RAL 9007NOTE: Due to artifacts of the printing process, the colors depicted here may not correspond exactly to the colors of actual doors. Please see the RAL or NCS samples.
Retouching
On request, Ninz also provides touch-up paint (nitro/synthetic) in 1,00 kg cans in the necessary RAL tint.
Protection
Since the gates are designed for internal usage, they should always be protected from atmospheric agents and direct sunlight.
Exterior uses require paints that are specially designed for this type of use (on request).
ATTENTION! External installation of gates require various measures for preventing product degradation, such as:
- The gates should always be protected from bad weather. Permanent damage may result if water seeps inside the door leaf. Provide canopies or roofi ng to protect newly installed and existing products.
- Avoid darker colors for gates which will be exposed to direct sunlight. Sheet metal can heat up and cause warping of the door leaf which could compromise the functionality of the door itself.
PULLEY TACKLES FOR SELF-CLOSURE
Pulley tackles serve to ensure the full self-closure of sliding gates which are wider than they are tall.
Maximum width WITHOUT TACKLES: (H-800) x 2
“Normal” pulley tackles
2 pulleys and standard counterweight box:
- for gates wider than (height H – 800) x 2 and shorter than (height H – 800) x 4
- minimum space required on rebate side 250 mm
- for geared counterweight: required space on the opening side L + 400 mm
“Special” pulley tackles
2 pulleys and augmented counterweight box:
- for gates wider than (height H – 800) x 4 and shorter than (height H – 1150) x 6
- minimum space required on rebate side 350 mm
- for geared counterweight: required space on the opening side L + 500 mm
“R” pulley tackles
3 pulleys and larger counterweight box:
- for gates wider than (height H – 1150) x 6 and shorter than L=7000 mm
- minimum space required on rebate side 350 mm
- for geared counterweight: required space on the opening side L + 500 mm
VT – VISCOTROLER®
ACCIDENT PREVENTION DEVICE
Gates should always be equipped with an automatic device that controls the feed speed of the door during automatic closing.
After the critical moment when automated re-closure has been initiated, door speed increases progressively in proportion to opening time and door weight. During emergency situations, the energy that develops could
cause serious injury/damage to people or objects within its range of motion. The hydraulic V.T. VISCOTROLLER® rotor makes it possible to set a constant closing speed in the range of 0.05 to 0,25 m/sec.
ATTENTION! For purposes of accident prevention, gates should always be equipped with a feed-in brake to regulate closing speed. Customers who choose not to include the feed-in brake assume full responsibility for possible consequences.

FEED-IN IMPACT ABSORBER
Mandatory accessory for one- and two-leaved sliding gates. Compression energy on the shaft is absorbed by slowing the flow of a fluid by means of an adjustable limiter valve. The shock absorber of the shaft is re-armed when the gate is re-opened.

ELECTROMAGNETS
Gates operation mode with electromagnets (on request): the gate is usually left open. The counterweight is always hooked to the leaf and closure occurs whenever the electric current to the electromagnet is interrupted.
For smoke/heat detection systems, control unit and power supply, see the dedicated page in the accessories doors section of the present website.

Technical data for the CC600N electromagnet per leaf for up to 12 m2 of wall opening | |
---|---|
primary power supply | 24 V DC |
voltage tolerance | ± 10% |
nominal current | 125 mA |
nominal power | 3 W |
insertion duration | 100% |
withstand force | approx. 61 Kg. |
operational temperature | 0°C ÷ +50°C |
operational temperature at 20°C | 45°C |
magnetic residue | null |
Technical data for the CC1400N electromagnet per leaf for more than 12 m2 of wall opening | |
---|---|
primary power supply | 24 V DC |
voltage tolerance | ± 10% |
nominal current | 200 mA |
nominal power | 5 W |
insertion duration | 100% |
withstand force | approx. 143 Kg. |
operational temperature | 0°C ÷ +50°C |
operational temperature at 20°C | 60°C |
magnetic residue | null |
EC marked in conformity with STANDARD EN 1155
GEARED REI 120 MONOLATERAL
Telescopic Gates
On request due to space limitations on the rebate side, slidinggates may also be supplied with geared and/or out-ofalignment counterweights.
A 100 mm overlap of the leaf must be ensured regardless. While ordering, please specify whether the rebate is NORMAL or SPECIAL.
ATTENTION!
Counterweight version, opposite side with normal rebate
*After the gate has been installed, building of the additional apron is the buyer’s responsibility and duty
INTERNAL NIGHT LOCK
On request, Telescopic Gates may be equipped with night locks with cylinders to pass.
Utilization of this type of mechanism with gates should be indicated while ordering.
CROSS BEAMS
Cross beam made of 100 x 200 mm insulated hollow metal profile for REI 120 one- or two-leaved Telescopic Gates . Up
to L = 2500 ready for lateral attachment, plus additional ceiling attachment for greater widths. Covering/finishing
of the beam with 2 sheets of 12.5 mm plasterboard is the customer’s responsibility.
GENERAL NOTES:
All rights reserved.
No reproduction (partial or total) without prior authorization by Ninz.
Ninz reserves the right to modify the product.
Installation should be executed by qualified technicians.
Modifications may only be made as indicated in the installation instructions.
Original NINZ replacement parts must be used for all repair work.