MAC® – Multifunctional access control

MAC MULTIFUNCTIONAL SYSTEM

The MAC system allows the possibility to open the door using the same components from a normal door.
The peculiarity of the MAC system is that it concentrates all of the command and control functions in the lock, which simplifies the electrical part in the fitting.

Installation on the door…..

The MAC system offers multiple advantages, such as:

  • possibility of 12 V AC/DC or 24 V AC/DC power supplies, which avoids problems due to inadequate voltage
  • low current absorption:
    • at 12 V the startup current is 500 mA for the first 5-6 sec., before changing to a 250 mA maintenance current
    • at 24 V the startup current is 1 A for 300 millisecond., before settling to 500 mA for 4-5 sec. and finally changing to a 250 mA maintenance current for the remaining 25 sec.
  • timer incorporated, time set at 30 sec. with automatic reset (zeroing of the timer) every time the door is opened, eliminating the need for external timers
  • red/green LED on the backplate to prevent useless forcing of the handle by signaling whether the opening system is active or not
  • continuous handle activation (always open when desired)
  • remote LED for remote signaling of lock activation/deactivation
Diagram of components

Nylon and stainless steel handles with red & green LED’S

The MAC system comes pre-assembled with the door, including the wiring inside the door leaf and the electrical contacts between the leaf and the frame. Included pre-assembled on the door: anti-panic lock with solenoid and electronic chip with timer incorporated (1), double electrical contacts between leaf and frame (2), internal wiring inside the leaf (3) Included in the package: handle and backplate with red/green LED and connectors (4) Not included: power supply for doorframe contacts (5), opening button and command accessories (6)

MAC 1 SYSTEM

Operation mode The MAC 1 system controls access from the pull side of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates the handle, while opening is always possible from the push side by means of the panic bar or emergency handle. Activation of the handle is signaled by illumination of the “green LED,” while the “red LED” indicates when the handle is idle. Both LEDs are off when no power is being supplied.

Time mode In this mode, the activation time lasts 30 seconds before the handle is returned to idle. If the door is opened within the 30 seconds, the timer is automatically reset to zero.
Continuous mode “open setting”: in this mode, handle activation is controlled by an electrical switch (not included) that provides continuous power to the MAC 1 lock. The green LED remains lighted, being turned off only from the time the door is opened until it is fully closed once again.

MAC 2 SYSTEM

Operation mode The MAC 2 system controls access from both sides of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates both handles. Activation of both handles is signaled by illumination of the “green LED,” with the “red LED” signaling when the handles are idle. Both LEDs are off when no power is being supplied.

Time mode In this mode, the activation time lasts 30 seconds before the handle is returned to idle. If the door is opened within the 30 seconds, the timer is automatically reset to zero.
Continuous mode “open setting”: in this mode, handle activation is controlled by an electrical switch (not included) that provides continuous power to the MAC 1 lock. The green LED remains lighted, being turned off only from the time the door is opened until it is fully closed once again.
MAC 1 can be combined with any BM type panic bar and M3 emergency handles(to be ordered on the side).
MAC 2 standard delivery can be combined with M1,black nylon handle. Upon request an M1X stainless steel handle can be delivered (to be ordered on the side).

M1

NOTE :
Both systems have been REI 120 fire-tested to ensure compliance of the certified product

Comments are closed.