DOOR CLOSER
The door closer regulates the closure of the door so that the door leaf returns properly to its final closed position after being released.
Regulation is influenced by closure force, speed and the final impact.
Although Univer and Proget doors are equipped with spring hinges for automatic closure, the installation of door closers is recommended for wide and/or heavy doors and/or in the presence of windows on the leaf.
The door closer product is addressed by EU directive 89/106/CEE, which means it is subject to CE marking.
CE marked in conformity with EN 1154.
Rever, Univer and Proget doors are available, on request, with an overhead CP1 door closer with a silver-colored scissor arm.
The CP1 can be used for fire rated doors and is classified for 180° closure with a force varying from 3 to 4.
Proget doors ordered with CP1 are provided with pre-drilled installation holes on the door leaf and the frame. Standard Rever, Univer and Proget doors include internal reinforcements for the CP1 application.

CE marked in conformity with EN 1154.
On request Rever, Univer and Proget doors are available with an overhead CP2 door closer with slide channel. Relative to the CP1, the advantage of this system is the absence of a protruding arm.
The CP2 is suited for use on fire rated doors and has been classified for 180° closure with force level 4.
Proget doors ordered with CP2 are provided with pre-drilled installation holes on the door leaf and the frame. Standard Rever, Univer and Proget doors include internal reinforcements for the CP2 application.

CE marked in conformity with EN 1154 and EN 1155.
The CP2–EMF differs from the CP2 in that it has an electro-mechanical hold-open device that allows the door leaf to be locked at an angle ranging from 80° to 120°. During alarms or power outages, the hold-open device is unlocked and the door is closed by the door closer.
The CP2-EMF can be used on fire doors and has a maximum opening range of 120°, with a closing force set at 4.
Proget doors ordered with CP2-EMF are provided with pre-drilled installation holes on the door leaf and the frame. Standard Univer doors include internal reinforcements for the CP2-EMF application.


maximum opening in the absence of obstacles | |||||||
Model | one-leaved door | active leaf | secondary leaf | power supply | absorption | EC certification | standard |
---|---|---|---|---|---|---|---|
CP1 | 180° | 180° | 180° | - | - | 0432-BPR-0054 | EN 1154 |
CP2 | 180° | 180° | 180° | - | - | 0432-BPR-0051 | EN 1154 |
CP2 EMF | 120° | 120° | 120° | 24 Vcc | 58,3 mA | 0432-BPR-0051 0432-BPR-0025 |
EN 1154 EN 1155 |
CLOSING REGULATOR
Closing regulators administer the closure of two-leaved doors so that the secondary leaf is overlaid on the active leaf upon final closure. This is why it is mandatory to apply closing regulators to all two-leaved fire doors.
There are two systems for applying it to the door:
- separated from the self-closing system of the spring hinge or the door closer
- incorporated into the closure system of the door closer
Closing regulators are addressed by EU directive 89/106/CEE, which means they are subject to CE marking.
CE marked in conformity with EN 1158.
The RC/STD closing regulator device is distinct from the door closer and is a standard element of all Univer and Proget two-leaved fire doors.
In Proget doors the closing regulator is inserted into the upper horizontal groove of the frame, while in Univer doors it is supplied separately with an anchoring rod to be installed on site. In comparison with other regulators which are separate from the door closer, the advantage of the RC/STD regulator is that it is not visible when the door is closed.
The RC/STD regulator is suited for use on fire doors and is classified for forces ranging from 3 to 5.


CE marked in conformity with EN 1154 and EN 1158.
On request, two-leaved Univer and Proget doors are available with an RC2 regulator in place of the RC/STD.
The RC2 closing regulator system is incorporated into the door closer, and consists of 2 CP2 with force EN 4 with a slide channel and a regulator integrated in the upper sliding guide. The entire system is silver colored.
The RC2 system presents clear advantages:
- no protruding door-closer arms
- regulator concealed in the upper guide (even when the door is open)
- controlled closure of both leaves
The RC2 regulator is suited for use on fire doors and is classified for both door closers with force EN4.
Minimum wall opening width of 1200 mm and minimum of 370 mm for the secondary leaf.
Proget doors ordered with RC2 are provided with pre-drilled holes for the installation of 2 CP2 door closers on the leaves and the slide channel on the frame. The installation holes in Univer doors need to be drilled on site for anchoring to the internal reinforcement of the leaves.

CE marked in conformity with EN 1154, EN 1158 and EN 1155.
The RC2–EMF1 system differs from the RC2 in that it has an electro-mechanical hold-open device that allows the door leaf to be locked at an angle ranging from approx. 80° to 130°. The active leaf is held open by the closing regulator system. During alarms or power outages, the hold-open system is unlocked and the door is closed by the door closer. The entire system is provided in the standard silver color.
The RC2-EMF1 system presents multiple advantages:
- possibility of holding the leaves open in the desired position
- no visible magnets
- no protruding door closer arms
- regulator concealed in the upper guide (even when the door is open)
- controlled closure of both leaves
The RC2-EMF1 system is suited for use on fire rated doors and is classified for both door closers with force level EN4. Minimum wall opening width of 1200 mm and minimum of 370 mm for the secondary leaf.
Proget doors ordered with RC2-EMF1 are provided with pre-drilled installation holes on the door leaf and the frame. The Univer door series includes internal reinforcements for application of the two door closers.

maximum opening in the absence of obstacles | ||||||
Model | active leaf | secondary leaf | power supply | absorption | EC certification | standard |
---|---|---|---|---|---|---|
RC/STD | 180° | 180° | - | - | 0425-ICIM-1153 | EN 1154 |
RC2 | 180° | 180° | - | - | 0432-BPR-0051 0432-BPR-0026 |
EN 1154 EN 1158 |
RC2-EMF1 | 180° | 130° | 24 Vcc | 58,3 mA | 0432-BPR-0051 0432-BPR-0025 0432-BPR-0026 |
EN 1154 EN 1155 EN 1158 |