MAC MULTIFUNCTIONAL SYSTEM
ENGLEZA!!!!Sistemul MAC face posibila deschiderea usii folosind aceleasi componente ca si in cazul unei usi normale.
Particularitatea sistemului MAC este ca concentreaza toate functiile de comanda si control in incuietoare, ceea ce simplifica partea electrica in montaj.
Installation on the door…..
The MAC system offers multiple advantages, such as:
- possibility of 12 V AC/DC or 24 V AC/DC power supplies, which avoids problems due to inadequate voltage
- low current absorption:
- at 12 V the startup current is 500 mA for the first 5-6 sec., before changing to a 250 mA maintenance current
- at 24 V the startup current is 1 A for 300 millisecond., before settling to 500 mA for 4-5 sec. and finally changing to a 250 mA maintenance current for the remaining 25 sec.
- timer incorporated, time set at 30 sec. with automatic reset (zeroing of the timer) every time the door is opened, eliminating the need for external timers
- red/green LED on the backplate to prevent useless forcing of the handle by signaling whether the opening system is active or not
- continuous handle activation (always open when desired)
- remote LED for remote signaling of lock activation/deactivation
The MAC system comes pre-assembled with the door, including the wiring inside the door leaf and the electrical contacts between the leaf and the frame. Included pre-assembled on the door: anti-panic lock with solenoid and electronic chip with timer incorporated (1), double electrical contacts between leaf and frame (2), internal wiring inside the leaf (3) Included in the package: handle and backplate with red/green LED and connectors (4) Not included: power supply for doorframe contacts (5), opening button and command accessories (6)


MAC 1 SYSTEM
Operation mode The MAC 1 system controls access from the pull side of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates the handle, while opening is always possible from the push side by means of the panic bar or emergency handle. Activation of the handle is signaled by illumination of the “green LED,” while the “red LED” indicates when the handle is idle. Both LEDs are off when no power is being supplied.
MAC 2 SYSTEM
Operation mode The MAC 2 system controls access from both sides of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates both handles. Activation of both handles is signaled by illumination of the “green LED,” with the “red LED” signaling when the handles are idle. Both LEDs are off when no power is being supplied.


————————————————————-Sfarsit subcapitol
“ELM/MT”, MULTI-VOLTAGE ELECTRIC HANDLE
The MAC 1 system controls access from the pull side of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates the handle, while opening is always possible from the push side by means of the panic bar or emergency handle. Activation of the handle is signaled by illumination of the “green LED,” while the “red LED” indicates when the handle is idle. Both LEDs are off when no power is being supplied. The illumination of a green LED and sounding of an acoustic signal (buzzer) indicate handle activation, while a red LED indicates deactivation.
When ordered together with the door, the ELM/mt system includes:
electric handle, electrical contacts between the leaf and the frame, power cable inside the door connected to electrical contacts, command panel, lock and fixing screws.
If ordered separately from the door, the system includes: electric handle, command panel and fixing screws.
| Technical data | |
|---|---|
| power supply | 12 Vac/Vdc – 24 Vac/Vdc |
| current absorbed at 12 V | 500 mA |
| current absorbed at 24 V | 200 mA |
| startup current at 12 V | 700 mA |
| startup current at 24 V | 300 mA |

ELM/CISA MULTI-VOLTAGE CISA ELECTRIC HANDLE
Controlled door opening system that employs an electronic device to activate the handle. Equipped with a separate timer (for insertion into the switch box) which can be set for different opening times: from a minimum of 0,1 second to a maximum of 10 days. Equipped with green LED that signal activation of the handle. The ELM/cisa system includes: electric handles, 2 meters of power cable, cable sleeve for the connection between the leaf and the frame, 8/9 square spindle, fixing screws, adjustable timer packaged separately.
| Technical data | |
|---|---|
| power supply | 12 Vac/Vdc – 24 Vac/Vdc |
| current absorbed | 330 mA |
| startup current | 800 mA |
| operational temperature | -20°C ÷ +80°C |
| max. relative ambient humidity | 95% |
NOTE The electric handle requires assembly.

PANIC BARS FOR COMBINATION WITH ELM/MT SAU ELM/CISA ELECTRIC HANDLES
The controlled opening direction is from the pull side of the door (electric handle side). Locking the lock by key blocks the electric handle functioning, while opening is still possible via the panic bar on the push side. Use: one- or two-leaved doors for anti-panic exits when access control is desired on the pull side.
Exus
Twist
SlashEMERGENCY HANDLES FOR COMBINATION WITH ELM/MT OR ELM/CISA ELECTRIC HANDLES
MSC MCC/SEMERGENCY HANDLES FOR COMBINATION WITH ELM/MT ELECTRIC HANDLES
M3 HOT-CIL
————————————————–Sfarsit subcapitol
ELECTROMAGNETIC SENSOR
……………lipseste capitolul!
————————————————–Sfarsit subcapitol
DOOR BLOCKING ELECTROMAGNET 13700 TD
This system is for use in special situations when the doors remain closed and should only be opened with electrical consent. The electrically powered electromagnet holds the door closed with a holding force of approximately 300 kg, rendering the action of the handle ineffective. Only electrical commands (badge reader, key button, etc.) or electrical consent from the fire detector system can deactivate the electromagnet making a door opening possible.
Operation mode The door is held closed by the electromagnet (01) and the bolt of the lock. Opening from the outside can happen via magnetic card (04) using the Badge reader (02) of the card control system or any other system of choice and by retracting the bolt using the handle or key. From the inside, the deactivation of the electromagnet is caused by the unlock button (03) (also remotely) or with the same system used for the pull side, while the locking bolt must still be retracted using the handle or key. The activated electromagnet signals its state with a red LED, whereas the green LED signals the temporary deactivation. Further a relay AC/DC signaling the electromagnetic state is supplied.

| Technical data | |||
|---|---|---|---|
| model | 13700 TD | withstand force | fino a 300 Kg. |
| power supply | 12/24 Vdc | time delay | 0 ÷ 90 sec. |
| current absorbed at 12 V | 500 mA | electrom. compatib standard | EMC – UNI CEI 70011 |
| current absorbed at 24 V | 250 mA | certificate Nr. | 0123/02 |
COMPONENTS INCLUDED WITH THE ELECTROMAGNET CONTROLLED OPENING SYSTEM
For Proget doors
Electromagnet 13700 TD holding force 300 kg, 12/24 V DC, fastener plate, anchor with stainless steel fastener backplate.
For Rever/Univer doors
Electromagnet 13700 TD withstanding force 300 kg, 12/24 V DC, fastener plate and angle bar, anchor with stainless steel fastener backplate.
Control system:
- “Access” code keypad
- Card-based control system
- Biometric “TOCA access” reader
- Unlock button
NOTE :
Detailed specifications for the Control system are found on the “Command accessories” page.

POWER SUPPLY/COMMAND ACCESSORIES
“Access” code keypad Power supply 12-18 V AC/V DC with 10 numeric buttons plus an Enter key, including control unit for 1 door and timer incorporated (0,5÷25 sec.). Up to 500 recordable different codes, composed from 1 to 6 digits.



- max. Nr. 10 MAC® Multifunction Access Control *
- or max. Nr. 5 13700 TD Electromagnets
- or max. Nr. 5 ELM/mt Electric handles *
- or max. Nr. 8 ELM/cisa Electric handles *
* provided that they are not commanded simultaneously




M3 HOT-CIL