Steel Fixed Windows

REI 30 OR REI 60 WITH BLOCK FRAME

  • Frame with a weight-bearing cold-formed hollow steel profile frame of 15/10 mm thickness, internally insulated with asbestos-free anorganic silicate material. Cross beams and/or uprights are positioned according to manufacturing criteria.
  • Fire resistant glazing is supplied un-mounted, and consists of extra-clear float panels with thermo-expansive
    fire-proof material interposed.
  • Special finishing with thermoset powders, color chosen from our wide variety (see “painting” page).
  • Subframe to be ordered separately, made of hollow galvanized steel profiles with anchors for mortar fixing.
  • NON-CERTIFIED EXECUTION. Goods come with the glazing producer’s certification only, with no declaration of conformity or identification plate.
Data table REI 30 REI 60
casing thickness 50 mm 50 mm
glass door weight 40 kg/m2 55 kg/m2
approx. glass thickness 15 mm 23 mm
maximum dimensions L x H 1600 x 2300 1600 x 2800
maximum dimensions recommended for each glazed panel approx. 2 m2 approx. 2 m2

NOTE
For purposes of handling, transport and installation plus the risk of breaking the glass, the manufacturer reserves the right, on a case by case basis, to decide whether to use 2 or more glazed panes while making windows.
The transverse and/or upright inside each window are invoiced as separate items. Price supplements are required for glazed panes with surface areas greater than 2.0 m2.
Any telescopic joints which might be required to reduce the size requirements
for transport and on-site manoeuvring shall be invoiced as separate items.

ATTENTION
These types of fire closures are required for internal compartmentalization and should be installed in areas that are protected from direct sunlight, other sources of heat and atmospherics agents. The use of suitable colors and glasses is required for windows located in areas which are partially exposed to direct sunlight.

REI 60 WITH FRAME EMBEDDED INTO THE WALL

    • Frame made of 50 x 30 mm hollow steel profile with glass stops and 10 x 3 mm aerstop sealing.
    • Fire rated glass is supplied un-mounted, and consists of float panels with the interposition of thermo-expansive
      fire proof material.
    • Prepared for attachment with plugs and inside the wall beyond the reveal on block frames.
    • Frame finished with green anti-rust (primer).
    • NON-CERTIFIED EXECUTION. Goods come with the glass producer’s certification only, with no declaration of conformity or identification plate.
Data table REI 60
casing thickness 50 mm
glass door weight 55 kg/m2
approx. glass thickness 21 mm
maximum dimensions L x H 1200 x 2100

NOTE
Execution is only possible with a single glazed pane without any transverse and/or upright dividers.
This glass type is for internal use only.

REI 120 WITH FRAME EMBEDDED INTO THE WALL

      • Frame made of 80 x 30 mm hollow steel profiles with glass stops and 10 x 3 mm aerstop sealing.
      • Fire rated glass is supplied un-mounted, and consists of float panels with the interposition of thermo-expansive fire proof material.
      • Prepared for attachment with plugs and inside the wall (out of sight).
      • Frame finished with green anti-rust (primer).
      • NON-CERTIFIED EXECUTION. Goods come with the glass producer’s certification only, with no declaration of conformity or identification plate.
Data table REI 120
casing thickness 80 mm
glass door weight 120 kg/m2
approx. glass thickness 52 mm
maximum dimensions L x H 1200 x 2100

NOTE
Execution is only possible with a single glazed pane without any transverse and/or upright dividers.

GENERAL NOTES
The use of suitable colors and glasses is required for doors located in areas that are partially exposed to direct sunlight or other heat sources. The casing must not be exposed to atmospheric agents in any case. For special instructions and recommendations regarding fire rated glass, see the “Notices” reported on the last page of the glass door accessories section of the present website.

 

All rights reserved. No reproduction (partial or total) without prior authorization
by Ninz.

Ninz reserves the right to modify the product. Installation should be executed by qualified technicians. Modifications may only be made as indicated in the installation instructions.
Original NINZ replacement parts must be used for all repair work.