WHAT DEFINES THEM ?
REI120 and REI180 fire rated gates are available with horizontal sliding.
The field of application includes the closure of large openings and/or special usage conditions in the dimensions requested by the customer. Gates are supplied with leaves made with flush panels of insulated sheet metal, top tubular
tracks, protective carters, counterweights, thermal or electromagnetic fuses and finished with a base coat or RAL colors, plus other accessories required for the correct functioning of the product.
Standards
The gates are certified in accordance with the UNI 9723 standard in compliance with the ministerial provisions in effect.
Opening direction
The opening direction needs to be specified when the order is placed.
Two-leaved gates available in the following classes:

ATTENTION! Fire compartmentalization elements should always be used properly. They are only designed for installation in spaces and constructions that are vertically aligned and flush.
Compartmentalization for interiors is for areas that are not subject to strong air currents. Installation to be executed by specialized technicians only. For special applications consult with our technical office.
The holding system for the gate is chosen by the customer to conform with their own worksite needs and the anti-fire design (thermal fuse or electromagnet).
REI 120 ONE-LEAVED VERSION
The sliding gates series has the following characteristics:
Installation
On weight-bearing masonry walls or insulated steel or insulated steel structure.
Gate leaves
Made of continuous panels of hollow-core sheet metal insulated with appropriate materials. Assembly involves screwing the structure to pre-prepared horizontal profiles. Leaf thickness 80 mm.
Top guide track
For horizontal sliding, made of press-folded steel with predrilled holes for attachment using plugs (not included). Overhead sliding on low friction carriages. The extension of the floor-mounted guide track beyond the opening ensures the perpendicularity of the leaf. The top guide track is covered by a protection carter made of press-folded sheet metal.
Overlapping labyrinths
Made of press-folded steel.
Counterweight
For adjustable closure and protected by press-folded sheet metal carters, with counterstrike inset.
Door handles
Recessed on both sides.
Sealing
Thermo-expanding on all overlapping labyrinths and underneath the leaf.
Identification plate
Marking with reference information that is applied directly to the handle.
Finishing
With a base coat thermoset in a 160 degree C furnace, light turquoise pastel color (similar to NCS4020-B50G).
Packaging
Modules in disposable metal container.
Wall opening dimensions
Min. 600 x 500 mm, max. 6000 x 6000 mm (larger sizes on request).
Operation mode
Of the gate series with thermal fuse: the gate can stand still at any position. The counterweight remains hooked to the thermal fuse and only closes the gate when the fuse fails.
Weight
Of the sliding door: REI 120 approx. 50 kg/m2 of wall opening.
NOTE: Additional accessories are usually dependent on the size dimensions of the gates

NB: Guide track gradient of 2 mm/ml

*Variable dimensions for larger-sized gates
REI 180 ONE-LEAVED VERSION
In conformity with UNI 9723, the sliding gates series has the following features:
Installation
On walls consisting of weight-bearing masonry.
Gate leaves
Made of continuous modules of hollow-core sheet metal panels insulated with the appropriate materials. Assembly
involves screwing the structure to pre-prepared horizontal profiles. Leaf thickness 140 mm.
Top guide track
For horizontal sliding, made of press-folded steel with predrilled holes for attachment using plugs (not included).
Overhead sliding on low friction carriages. The extension of the floor-mounted guide track beyond the opening ensures
the perpendicularity of the leaf. The top guide track is covered by a protection carter made of press-folded sheet metal.
Overlapping labyrinths
Made of press-folded steel.
Counterweight
For adjustable closure and protected by press-folded sheet metal carters, with counterstrike inset.
Door handles
Recessed on both sides.
Sealing
Thermo-expanding on all overlapping labyrinths and underneath the leaf.
Identification plate
Marking with reference information that is applied directly to the handle.
Finishing
With a base coat thermoset in a 160 degree C furnace, light turquoise pastel color (similar to NCS4020-B50G).
Packaging
Modules in disposable metal container.
Wall opening dimensions
Min. 600 x 500 mm, max. 6000 x 6000 mm (larger sizes on request).
Operation mode
Of the gate series with thermal fuse: the gate can stand still at any position. The counterweight remains hooked to the thermal fuse and only closes the gate when the fuse fails.
Weight
Of the sliding door: REI 180 approx. 75 kg/m2 of wall opening.
NOTE: Additional accessories are usually dependent on the size dimensions of the gates

NB: Guide track gradient of 2 mm/ml

*Variable dimensions for larger-sized gates
REI 120 TWO-LEAVED VERSION
In conformity with UNI 9723, the sliding gates series has the following characteristics:
Application
On weight-bearing masonry walls or insulated steel or insulated steel structure.
Gate leaves
Made of continuous modules of hollow-core sheet metal panels insulated with the appropriate materials. Assembly
involves screwing the structure to pre-prepared horizontal profiles. Leaf thickness 80 mm.
Top guide track
For horizontal sliding, made of press-folded steel with predrilled holes for attachment using plugs (not included).
Overhead sliding on low friction carriages. The extension of the floor-mounted guide track beyond the opening ensures
the perpendicularity of the leaf. The top guide track is covered by a protection carter made of press-folded sheet metal.
Overlapping labyrinths
Made of press-folded steel.
Counterweight
For adjustable closure and protected by press-folded sheet metal carters, with counterstrike inset.
Door handles
Recessed on both sides.
Sealing
Thermo-expanding on all overlapping labyrinths and underneath the leaf.
Identification plate
Marking with reference information that is applied directly to the handle.
Finishing
With a base coat thermoset in a 160 degree C furnace, light turquoise pastel color (similar to NCS4020-B50G).
Packaging
Modules in disposable metal container.
Wall opening dimensions
Min. 1200 x 500 mm, max. 8000 x 6000 mm (larger sizes on request).
Operation mode
Of the gate series with thermal fuse: the gate can stand still at any position. The counterweight remains hooked to the thermal fuse and only closes the gate when the fuse fails.
Weight
Of the sliding door: REI 120 approx. 50 kg/m2 of wall opening.

NB: Guide track gradient of 2 mm/ml
Also executable with unequal leaves

*Variable dimensions for larger-sized gates
OPERATION MODE OF SLIDING FIRE GATES WITH ONE OR TWO LEAVES
The selection of the holding system should reflect the customer’s worksite needs and the anti-fire project.
Operation mode of gates equipped with thermal fuse:
The counterweight (1) does not load the gate and the operator (2) manually opens and closes the gates, which remains in the position it is left in. When the thermal fuse (3) is subjected to temperatures greater than 70° C, it breaks and causes the cable (4) to be released, so that the counterweight drags the gates to the closed position. The feed speed brake (5) prevents the gates from accelerating during closure. The feed-in impact absorber (6) softens the final feed-in impact of the closure.
Operation mode of gates equipped with electromagnet:
The counterweight (1) continuously loads the gate. The gate usually remains open, held in place by the electromagnet
(2). The counterweight closes the gate whenever the electromagnet lacks impulse current from the control unit or when the release button (3) is pressed. The feed speed brake (4) prevents the gate from accelerating during closure. The feed-in impact absorber (5) softens the final feed-in impact of the closure. The electromagnet must be connected with a power control unit and the related external smoke and heat detectors.

NOTE: The thermal fuse is only triggered when the temperature in the immediate vicinity rises above 70° C, and it does not respond to smoke. Its application, therefore, is not advisable when the gates are located outside the compartmentalization space and when a reaction to cold smoke is required.

NOTE: The gate closes on impulse from a control unit controlled by an external RFC detector, thus permitting automatic closure at temperatures lower than 70° C as well in the presence of cold smoke. This means that the gate can be installed in any position, even outside the compartmentalization space.
TOP GUIDE TRACK
Detail of the upper guide track for one and two-leaved sliding gates. The heights refer to wall openings which are perfectly vertically
aligned, installed properly and should those values should be considered indicative.
PAINTING
With ecologically formulated anti-corrosive epoxide primer. Minimum resistance to salt fog exposure: 300 hours
(A.S.T.M. B – 117 – 61). Basic anti-corrosion coating: Light turquoise pastel. Optional: fi nishing with satin topcoats from the selection of furnace polymerized RAL colors.
Group 01
Gates color: light turquoise pastel (similar to NCS4020B50G)
Group 02 (Basic anti-corrosion coating + satin topcoat finishing):
Cleaning
Water and neutral soap are recommended for the regular cleaning of our products. Do not use common cleaning products (see detergents) and/or other solvents. We shall not be held responsible for any problems that arise if these guidelines are not respected.
Re-painting
For re-painting, use the following procedure:
- sand and carefully wipe away any dust from the surfaces
- apply a base layer of opaque 2-component epoxide we recommend EPOX product Nr. 5203 beige 0059 made by ALCEA in Milan
- repaint the surfaces with your choice of lacquers or paints.
Group 03 (Basic anti-corrosion coating + satin topcoat finishing):
*Pre-approval of the sample is required.
Group 04 (Basic anti-corrosion coating + satin topcoat finishing):
Group 05 (Basic anti-corrosion coating only):
Basic anti-corrosion coating is available for all colors listed in group 02.
In general, all RAL tints are useable except for: RAL 1018, RAL 5005 and RAL 9007
NOTE: Due to artifacts of the printing process, the colors depicted here may not correspond exactly to the colors of actual doors. Please see the RAL or NCS samples.
Retouching
On request, Ninz also provides touch-up paint (nitro/synthetic) in 1,00 kg cans in the necessary RAL tint.
Protection
Since the gates are designed for internal usage, they should always be protected from atmospheric agents and direct sunlight.
Exterior uses require paints that are specially designed for this type of use (on request).
ATTENTION! External installation of gates require various measures for preventing product degradation, such as:
1. The gates should always be protected from bad weather. Permanent damage may result if water seeps inside the door leaf. Provide canopies or roofing to protect newly installed and existing products.
2. Avoid darker colors for gates which will be exposed to direct sunlight. Sheet metal can heat up and cause warping of the door leaf which could compromise the functionality of the door itself.
PULLEY TACKLES FOR SELF-CLOSURE
Pulley tackles serve to ensure the full self-closure of sliding gates which are wider than they are tall.
Maximum width WITHOUT TACKLES: (H-800) x 2
“Normal” pulley tackles
2 pulleys and standard counterweight box:
- for gates wider than (height H – 800) x 2 and shorter than (height H – 800) x 4
- minimum space required on rebate side 250 mm
- for geared counterweight: required space on the opening side L + 400 mm
“Special” pulley tackles
2 pulleys and augmented counterweight box:
- for gates wider than (height H – 800) x 4 and shorter than (height H – 1150) x 6
- minimum space required on rebate side 350 mm
- for geared counterweight: required space on the opening side L + 500 mm
“R” pulley tackles
3 pulleys and larger counterweight box:
- for gates wider than (height H – 1150) x 6 and shorter than L=7000 mm
- minimum space required on rebate side 350 mm
- for geared counterweight: required space on the opening side L + 500 mm

“Normal”/”Special” pulley tackles

“R”pulley tackles
VT – VISCOTROLER®
ACCIDENT PREVENTION DEVICE
Gates should always be equipped with an automatic device that controls the feed speed of the door during automatic closing.
After the critical moment when automated re-closure has been initiated, door speed increases progressively in proportion to opening time and door weight. During emergency situations, the energy that develops could
cause serious injury/damage to people or objects within its range of motion. The hydraulic V.T. VISCOTROLLER® rotor makes it possible to set a constant closing speed in the range of 0.05 to 0,25 m/sec.
ATTENTION! For purposes of accident prevention, gates should always be equipped with a feed-in brake to regulate closing speed. Customers who choose not to include the feed-in brake assume full responsibility for possible consequences.

FEED-IN IMPACT ABSORBER
Mandatory accessory for one- and two-leaved sliding gates. Compression energy on the shaft is absorbed by slowing the flow of a fluid by means of an adjustable limiter valve. The shock absorber of the shaft is re-armed when the gate is re-opened.

ATTENTION! Be careful not to damage the impact absorber shaft
ELECTROMAGNETS
Gates operation mode with electromagnets (on request): the gate is usually left open. The counterweight is always hooked to the leaf and closure occurs whenever the electric current to the electromagnet is interrupted.
For smoke/heat detection systems, control unit and power supply, see the dedicated page in the accessories doors section of the present website.

PEDESTRIAN DOOR
REI 120 sliding gates, with one or two leaves, may be equipped with a pedestrian door with or without a lower threshold. Pedestrian doors with thresholds and panic bars are not suitable for escape routes. The right or left opening direction should be specified by the customer during the ordering phase. By default pedestrian doors are inserted in the second panel, which is next to the panel with the handle. For additional information about the SLASH panic exit device, please see the dedicated pages in the panic exit device section of the present website.



Minimum gate dimensions required for insertion of pedestrian doors with or without threshold
Pedestrian | minimum FM dimensions | ||
door size | one leaved sliding gate | two-leaved sliding gate | |
---|---|---|---|
width | 850 | 1700 | 2800 |
1140 | 2000 | 3350 | |
height with threshold | 2090 | 2200*/2250** | 2200*/2250** |
height with threshold | 2000 | 2450 | 2450 |
* opening on wall side
** opening on side opposite the wall
Pedestrian door with threshold: If the FM H height lower to the measures
listed, the height of the pedestrian door is reduced
Pedestrian doors used along escape routes are at the customer’s own risk!

VERTICAL AND HORIZONTAL SHIMMING
Mandatory for gates with pedestrian doors equipped with panic bars and/or pedestrian doors towards the wall side. The counterweight box and the sliding leaf labyrinths are increased by 60 mm.
NOTE: For two-leaved sliding doors, vertical shimming should be calculated for both leaves.
Shimming needs to be ordered separately.
ATTENTION! *The plasterboard finishing (not included) should be installed on site after the guide track has been installed.

OPENING OF PEDESTRIAN DOOR TOWARDS THE OPPOSITE WALL WITH THE HANDLE
Horizontal and vertical shimming is not necessary.
OPENING OF PEDESTRIAN DOOR TOWARDS THE OPPOSITE WALL WITH THE SLASH PANIC BAR
The horizontal and vertical shimming is mandatory.
OPENING OF PEDESTRIAN DOOR TOWARDS THE SAME WALL WITH THE SLASH PANIC EXIT DEVICE
The horizontal and vertical shimming is mandatory.
ATTENTION! The threshold version of the pedestrian door with a panic

bar is not suited for escape routes.