“ELM/MT”, MULTI-VOLTAGE ELECTRIC HANDLE
The MAC 1 system controls access from the pull side of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates the handle, while opening is always possible from the push side by means of the panic bar or emergency handle. Activation of the handle is signaled by illumination of the “green LED,” while the “red LED” indicates when the handle is idle. Both LEDs are off when no power is being supplied. The illumination of a green LED and sounding of an acoustic signal (buzzer) indicate handle activation, while a red LED indicates deactivation.
When ordered together with the door, the “ELM/MT” system includes:
electric handle, electrical contacts between the leaf and the frame, power cable inside the door connected to electrical contacts, command panel, lock and fixing screws.
If ordered separately from the door, the system includes: electric handle, command panel and fixing screws.
Technical data | |
---|---|
power supply | 12 Vac/Vdc – 24 Vac/Vdc |
current absorbed at 12 V | 500 mA |
current absorbed at 24 V | 200 mA |
startup current at 12 V | 700 mA |
startup current at 24 V | 300 mA |

“ELM/CISA”, MULTI-VOLTAGE CISA ELECTRIC HANDLE
Controlled door opening system that employs an electronic device to activate the handle. Equipped with a separate timer (for insertion into the switch box) which can be set for different opening times: from a minimum of 0,1 second to a maximum of 10 days. Equipped with green LED that signal activation of the handle. The ELM/cisa system includes: electric handles, 2 meters of power cable, cable sleeve for the connection between the leaf and the frame, 8/9 square spindle, fixing screws, adjustable timer packaged separately.
Technical data | |
---|---|
power supply | 12 Vac/Vdc – 24 Vac/Vdc |
current absorbed | 330 mA |
startup current | 800 mA |
operational temperature | -20°C ÷ +80°C |
max. relative ambient humidity | 95% |
NOTE: The electric handle requires assembly.

PANIC BARS FOR COMBINATION WITH “ELM/MT” OR “ELM/CISA” ELECTRIC HANDLES
The controlled opening direction is from the pull side of the door (electric handle side). Locking the lock by key blocks the electric handle functioning, while opening is still possible via the panic bar on the push side. Use: one- or two-leaved doors for anti-panic exits when access control is desired on the pull side.



EMERGENCY HANDLES FOR COMBINATION WITH “ELM/MT” OR “ELM/CISA” ELECTRIC HANDLES

EMERGENCY HANDLES FOR COMBINATION WITH “ELM/MT” ELECTRIC HANDLES
M3 HOT-CIL